The ELOTEST M2 is a
universal one-hand tester for surfaces, drill holes and hidden structures. It
also measures the conductivity and layer thickness of all materials. The
ELOTEST M2 allows a DUAL frequency test with mix and covers the complete range
of frequency from 10 Hz to 12 MHz. It offers a signal optimization for static
and dynamic tests due to all filter functions (LP, HP, BP ). The sharp LCD
Display with LED illumination ensures an optimal visibility of the test signals,
even in direct sunlight. Integrated calibration bodies simplify and accelerate
on-site work. The device is operated with a well-structured keypad and clearly
assigned functions. This allows even unexperienced users to work with quickly
and safely. The user-friendliness is supported by clear text messages on the
screen.
Features
- Full frequency range: 10 Hz to 12
MHz
- Fully variable filters: low-pass,
high-pass and band-pass, for static and dynamic inspections
- High speed Impedance plane and
Time-Base modes
- Internal digital strip-chart
recorder
- Suitable for all types of probes
- Separate BNC connector for
parametric/single-coil probes (NO balancing load required!)
- Adapters/adapter cables for
various competitor probe connectors
- Easy to operate via pictographs
and text using only 9 keys
- Li-Ion battery for more than 8
hrs operation
- High-definition LCD display with
back-light and adjustable contrast, for indoor and outdoor use
- Higher performance at a cost effective price
Applications
- Manual inspection with
differential and absolute probes
- Multi-layer rotary inspection of
bore holes
- Testing for surface defects and
hidden structural defects
- Measuring corrosion and
conductivity
- Defect analysis of built-in tubes
with co-axial and rotating internal tubes probes
- Material properties/ hardness sorting
Specifications
User-Interface ELOTEST M2
- Pictograph-based, one-hand
operation via key pad with key-click
- 6 languages: English, German,
French, Italian, Swedish and Spanish
- Direct-function keys for
offset- and liftoff-compensation
- Programmable function key
- Intuitive operation using only
one submenu-level
Probe Connection
- 11-pin Fischer socket,
compatible with the 8-pin Rohmann connector
- BNC connector for parametric
probes (resonant probes)
- OEM probes to be connected via
an adapter or directly to the BNC connector
- Speed control for rotor (torque
compensated) in 10 steps (corresponds to approx. 900 rpm to 2700 rpm using
Rohmann standard rotors)
- Compensation of the probe
response signal for optimum signal dynamics
- Automatic test frequency
selection using the probe characteristics
- Automatic balancing of
single-coil probes using finely graduated, internal compensating loads (no
external elements required)
Frequency Range
- 10 Hz to 12 MHz, continuously
adjustable, display in Hz, kHz, MHz
- Adjustable driver current, from
0 % to 100 % in 2 % steps
- Frequency variation from
nominal less than 1 %; frequency stability 50 ppm
- Dual-frequency operation in
multiplex-mode
Gain
- Preamplification 0 to 60 dB in
0.5 dB steps (0 to 40 dB in 100 kHz range)
- Gain 0 to 60 dB in 0.5 dB steps
- Axis spread 0 to 20 dB in 1 dB
steps
- Automatic selection of
preamplification and gain
Phase
- 0-359.5° in 0.5° steps; step
size adjustable Filter
- Low-pass filter 1.3 Hz to 10
kHz in 40 steps
- Band-pass filter 0 Hz to 10
kHz; combination of HP and LP
- Selectable automatic filter for
rotor operation
LCD–Display
- LCD featuring long-life LED
backlight, 80 x 60 mm (3.15” x 2.36”)
- Temperature-compensated
contrast setting
- Resolution 320 x 240 Pixel;
refresh rate 75 Hz,
- 220,000 data samples/second, no
signal delay
- Signal display covering 100 %
of the screen; over 89 % with menu displayed
- 80° viewing angle
Display Modes
- Impedance plane / spot display
(X/Y), available for all probes
- Time-base/sweep display (Y/t),
5 ms to 60 s in 17 steps; synchronized
- Simultaneous X/Y- and
Y/t-display (dual-screen mode)
- Reference signal may be
displayed in the background
- 2 screen grid sizes with
adjustable intensity
- Selectable display range: X/Y
center – X/Y center bottom – X/Y bottom right
- Freely positionable zero/null
point
- Automatic trigger during rotor
operation
- Simultaneous multi-signal
display during multi-frequency operation
- Persistence: 0.1 s to 70 s
adjustable in 12 steps
- On-screen signal storage;
cleared manually or via auto-erase (2 - 80 s)
Gates/Alarm
- Alarm: optical and acoustic
- Active in all display modes;
may be inverted
- Adjustable gates: +Y-gate,
Box-gate, Circle-gate with adjustable flat in the Y-direction
Parameter Settings/Image Memory
- 99 user settings may be
programmed, stored and recalled
- 50 application-related factory
default settings (cannot be overwritten)
- 32 signal memories incl.
parameter settings for documentation
- Parameter setups and images may
be named using alphanumerical characters
- Image and parameter data may be
printed and transmitted to personal computer
- Long-term recording (strip
chart) of X- and Y-signals, from 20 s to 24 hours; 90,000 min/max-values
(envelope, without data-loss)
- Data storage maintained
(backup-battery)
Conductivity Measurement
- Measurement in % IACS or MS/m
from 1 % IACS to 110 % IACS.
- Measuring frequency: 60 kHz
- Calibration using 2
individually adjustable calibration points
Coating Thickness Measurement
- Measurement of non-conductive
layers on conductive non-ferromagnetic materials
- Measurement range up to 1000 µm
or 40 mils
Multi-Frequency Operation
- 2-frequency multiplex
- Multiplex rate up to 1 kHz
- Both frequencies fully
adjustable, independent of each other
- Signal mix-function to suppress
unwanted effects
Interfaces
- RS232-interface for PC or
printer (HP Laserjet and Epson LX80)
Operation with Lithium-Ion Batteries
- Without background light and
rotor: approx. 8 hours
- With light and rotor: approx. 6
hours
- Indication of remaining charge
capacity
- Acoustic and optical alarm for
low battery
- Charge time Li-Ion battery from
0 % to 70 % - approx. 1 hour
- Charge time Li-Ion battery from
0 % to 100 % - approx. 6 hours
- Battery may be replaced in less
than 10 seconds
Ambient Conditions
- Operation between -20 °C (-4
°F) and 50 °C (122 °F) at max. 85 % rel. humidity (non-condensating)
- Storage between -30 °C (-22 °F)
and 80 °C (176 °F) at max. 85 % rel. humidity (non-condensating)
- Battery charge between 0 °C (32
°F) and 40 °C (104 °F) at max. 85 % rel. humidity (non-condensating)
Dimensions
- • Ergonomic design
- Max. dimensions: 320 mm (12.6“)
/ 125 mm (4.92“) / 73 mm (2.87“) (length/width/depth)
- At display: 120 mm (4.72”) /
107 mm (4.21”) / 53 mm (2.08”) (length/width/depth)
- At handle: 185 mm (7.2”) / 63
mm (2.48”) / 44 mm (1.73”) (length/width/depth)
Weight
- Ergonomically optimized center
of gravity (inside the operator's hand)
- Instrument without battery
approx. 530 g (1.1 lbs)
- Lithium-ion battery approx. 390
g (0.85 lbs)
- Wide-range charger approx. 560
g (1.23 lbs)
- Table-top charger (docking
station) approx. 1,070 g (2.35 lbs)
Power Supply (Options)
- Li-ion battery (14.8 V/2300
mAh)
- Mains operation with desk-top
docking station (88 – 265 VAC/47 – 440 Hz) featuring intelligent battery
management separately for instrument and second battery pack
Calibration Standards (optional)
- Calibration standards: titanium, aluminum, stainless and ferromagnetic steel with reference notches: 0.2/0.5/1.0 mm (0.039/0.02/0.008 inch) deep; may be inserted into the instrument handle
Setting Manager
- PC-software to archive
settings, generate test reports and screen shots
ELOTEST M2
- Product Code: ELOTEST M2
- Availability: Out Of Stock